Formula and method
Flow scales with square root of differential-pressure ratio; rail gauge pressure = differential pressure + manifold gauge pressure.
New flow = rated flow × √(new differential pressure / rated differential pressure)
Rail gauge pressure = target differential pressure + manifold gauge pressure
Understanding your inputs
- Injector rated static flow
- Enter lb/h. Accepted input range: 0.000001–1000.
- Rated rail-to-manifold differential pressure
- Enter psi. Accepted input range: 0.000001–200.
- Proposed rail-to-manifold differential pressure
- Enter psi. Accepted input range: 0.000001–200.
- Manifold gauge pressure at target condition
- Enter psi. Accepted input range: -14–100.
Worked example
Use the displayed example: Injector rated static flow: 36 lb/h; Rated rail-to-manifold differential pressure: 43.5 psi; Proposed rail-to-manifold differential pressure: 58 psi; Manifold gauge pressure at target condition: 10 psi. Ideal injector flow at new differential pressure is 41.569 lb/h. Companion outputs use the same example inputs unless separately labelled.
Example inputs
- Injector rated static flow
- 36 lb/h
- Rated rail-to-manifold differential pressure
- 43.5 psi
- Proposed rail-to-manifold differential pressure
- 58 psi
- Manifold gauge pressure at target condition
- 10 psi
Default result: Ideal injector flow at new differential pressure: 41.569 lb/h.
Assumptions
- The example is Injector rated static flow: 36 lb/h; Rated rail-to-manifold differential pressure: 43.5 psi; Proposed rail-to-manifold differential pressure: 58 psi; Manifold gauge pressure at target condition: 10 psi.
- Illustrative inputs are editable assumptions. A numerical result does not establish component compatibility or a measured vehicle rating.
Limitations
- Square-root scaling assumes stable discharge behavior. Injector limits, pump flow at pressure and regulator capacity still govern hardware choice.
- Illustrative inputs are editable assumptions. A numerical result does not establish component compatibility or a measured vehicle rating.
Common mistakes
- Entering values in units different from the selected or displayed labels (lb/h, psi, psi, psi).
- Only at zero gauge manifold pressure. Differential pressure is rail minus manifold; under boost, rail gauge pressure must rise to retain the same differential.
- Combining measurements taken at different operating points or temperatures.
Sources and methodology
Method reviewed October 1, 2026. Formulas are implemented independently; references explain the dimensions, ratings or application requirements.
- Holley EFI — installation and sizing reference ↗
Fuel injector sizing using horsepower, BSFC, count and duty cycle; square-root differential-pressure flow scaling. Density and reserves remain user inputs.
- NIST — SI conversion factors ↗
Declared mechanical horsepower, length, mass, volume and pressure unit conversions; dimensional calculations are derived independently.
Frequently asked questions
How does the injection pressure calculation work?
Flow scales with square root of differential-pressure ratio; rail gauge pressure = differential pressure + manifold gauge pressure.
Is gauge rail pressure the injector differential pressure?
Only at zero gauge manifold pressure. Differential pressure is rail minus manifold; under boost, rail gauge pressure must rise to retain the same differential.
What do the example values represent?
They demonstrate the method with editable inputs. Square-root scaling assumes stable discharge behavior. Injector limits, pump flow at pressure and regulator capacity still govern hardware choice.
How should I handle an invalid input?
Enter finite values in the stated units and ranges. Empty required fields, zero denominators and inconsistent geometry hide the previous result and show an input error. Reset example restores the documented scenario.