Formula and method
Per-injector static flow = power × BSFC / (injector count × duty fraction).
Static injector lb/h = target HP × BSFC / (injector count × duty fraction)
Existing duty % = 100 × HP × BSFC / (count × actual-rated injector lb/h)
cc/min = lb/h × 0.45359237 / density kg/L × 1000 / 60
Understanding your inputs
- Target brake engine horsepower
- Enter hp. Accepted input range: 0.000001–100000.
- Assumed BSFC at target operating point
- Enter lb/(hp·h). Accepted input range: 0.000001–5.
- Total active injector count
- Enter injectors, as a whole number. Accepted input range: 1–32.
- Selected maximum duty-cycle budget
- Enter %. Accepted input range: 0.000001–100.
- Fuel density for volume conversion
- Enter kg/L. Accepted input range: 0.000001–2.
- Existing injector static flow at operating differential pressure
- Enter lb/h. Accepted input range: 0.000001–1000.
Worked example
Use the displayed example: Target brake engine horsepower: 400 hp; Assumed BSFC at target operating point: 0.5 lb/(hp·h); Total active injector count: 8 injectors; Selected maximum duty-cycle budget: 80 %; Fuel density for volume conversion: 0.74 kg/L; Existing injector static flow at operating differential pressure: 36 lb/h. Required static flow per injector is 31.250 lb/h. Companion outputs use the same example inputs unless separately labelled.
Example inputs
- Target brake engine horsepower
- 400 hp
- Assumed BSFC at target operating point
- 0.5 lb/(hp·h)
- Total active injector count
- 8 injectors
- Selected maximum duty-cycle budget
- 80 %
- Fuel density for volume conversion
- 0.74 kg/L
- Existing injector static flow at operating differential pressure
- 36 lb/h
Default result: Required static flow per injector: 31.250 lb/h.
Assumptions
- The example is Target brake engine horsepower: 400 hp; Assumed BSFC at target operating point: 0.5 lb/(hp·h); Total active injector count: 8 injectors; Selected maximum duty-cycle budget: 80 %; Fuel density for volume conversion: 0.74 kg/L; Existing injector static flow at operating differential pressure: 36 lb/h.
- Illustrative inputs are editable assumptions. A numerical result does not establish component compatibility or a measured vehicle rating.
Limitations
- Existing flow must be rated at the actual rail-to-manifold differential pressure. Dead time, fuel compatibility and ECU control require separate verification.
- Illustrative inputs are editable assumptions. A numerical result does not establish component compatibility or a measured vehicle rating.
Common mistakes
- Entering values in units different from the selected or displayed labels (hp, lb/(hp·h), injectors, %, kg/L, lb/h).
- The same hourly fuel demand must be delivered while the injector is open for a smaller fraction of the cycle, so required static flow rises.
- Combining measurements taken at different operating points or temperatures.
Sources and methodology
Method reviewed October 1, 2026. Formulas are implemented independently; references explain the dimensions, ratings or application requirements.
- Holley EFI — installation and sizing reference ↗
Fuel injector sizing using horsepower, BSFC, count and duty cycle; square-root differential-pressure flow scaling. Density and reserves remain user inputs.
- NIST — SI conversion factors ↗
Declared mechanical horsepower, length, mass, volume and pressure unit conversions; dimensional calculations are derived independently.
Frequently asked questions
How does the fuel injector size calculation work?
Per-injector static flow = power × BSFC / (injector count × duty fraction).
Why does lower duty cycle require a larger injector?
The same hourly fuel demand must be delivered while the injector is open for a smaller fraction of the cycle, so required static flow rises.
What do the example values represent?
They demonstrate the method with editable inputs. Existing flow must be rated at the actual rail-to-manifold differential pressure. Dead time, fuel compatibility and ECU control require separate verification.
How should I handle an invalid input?
Enter finite values in the stated units and ranges. Empty required fields, zero denominators and inconsistent geometry hide the previous result and show an input error. Reset example restores the documented scenario.