Formula and method
Fuel mass = brake HP × BSFC; divide by fuel density for volume and add the supplied reserve.
Base pump L/h = HP × BSFC × 0.45359237 / density kg/L
Required pump delivered L/h = base × (1 + reserve fraction)
Understanding your inputs
- Target brake engine horsepower
- Enter hp. Accepted input range: 0.000001–100000.
- Assumed BSFC
- Enter lb/(hp·h). Accepted input range: 0.000001–5.
- Fuel density
- Enter kg/L. Accepted input range: 0.000001–2.
- Flow reserve above demand
- Enter %. Accepted input range: 0–200.
- Known delivered pump flow at actual operating pressure
- Enter L/h. Accepted input range: 0.000001–100000.
Worked example
Use the displayed example: Target brake engine horsepower: 400 hp; Assumed BSFC: 0.5 lb/(hp·h); Fuel density: 0.74 kg/L; Flow reserve above demand: 25 %; Known delivered pump flow at actual operating pressure: 255 L/h. Required delivered pump flow including reserve is 153.24 L/h. Companion outputs use the same example inputs unless separately labelled.
Example inputs
- Target brake engine horsepower
- 400 hp
- Assumed BSFC
- 0.5 lb/(hp·h)
- Fuel density
- 0.74 kg/L
- Flow reserve above demand
- 25 %
- Known delivered pump flow at actual operating pressure
- 255 L/h
Default result: Required delivered pump flow including reserve: 153.24 L/h.
Assumptions
- The example is Target brake engine horsepower: 400 hp; Assumed BSFC: 0.5 lb/(hp·h); Fuel density: 0.74 kg/L; Flow reserve above demand: 25 %; Known delivered pump flow at actual operating pressure: 255 L/h.
- Illustrative inputs are editable assumptions. A numerical result does not establish component compatibility or a measured vehicle rating.
Limitations
- Compare pump flow at actual rail pressure and supply voltage, not a free-flow marketing rating. Return-system recirculation and line loss are separate.
- Illustrative inputs are editable assumptions. A numerical result does not establish component compatibility or a measured vehicle rating.
Common mistakes
- Entering values in units different from the selected or displayed labels (hp, lb/(hp·h), kg/L, %, L/h).
- No. Use delivered flow at the actual rail pressure and electrical voltage. A free-flow rating can overstate usable delivery.
- Combining measurements taken at different operating points or temperatures.
Sources and methodology
Method reviewed October 1, 2026. Formulas are implemented independently; references explain the dimensions, ratings or application requirements.
- Holley EFI — installation and sizing reference ↗
Fuel injector sizing using horsepower, BSFC, count and duty cycle; square-root differential-pressure flow scaling. Density and reserves remain user inputs.
- NIST — SI conversion factors ↗
Declared mechanical horsepower, length, mass, volume and pressure unit conversions; dimensional calculations are derived independently.
Frequently asked questions
How does the fuel pump size calculation work?
Fuel mass = brake HP × BSFC; divide by fuel density for volume and add the supplied reserve.
Can I compare the result with free-flow pump ratings?
No. Use delivered flow at the actual rail pressure and electrical voltage. A free-flow rating can overstate usable delivery.
What do the example values represent?
They demonstrate the method with editable inputs. Compare pump flow at actual rail pressure and supply voltage, not a free-flow marketing rating. Return-system recirculation and line loss are separate.
How should I handle an invalid input?
Enter finite values in the stated units and ranges. Empty required fields, zero denominators and inconsistent geometry hide the previous result and show an input error. Reset example restores the documented scenario.