Formula and method
Compare the actual temperature reduction with the maximum reduction to the cooling medium.
Effectiveness = (Tin − Tout) / (Tin − Tcool) × 100
Understanding your inputs
- Charge temperature before intercooler
- Enter °C. Accepted input range: -50–500.
- Charge temperature after intercooler
- Enter °C. Accepted input range: -50–500.
- Cooling-air temperature
- Enter °C. Accepted input range: -50–100.
Worked example
Example inputs: Charge temperature before intercooler: 120 °C; Charge temperature after intercooler: 45 °C; Cooling-air temperature: 25 °C. Intercooler temperature effectiveness: 78.947 %. Independent companion modules use their separately labelled inputs.
Example inputs
- Charge temperature before intercooler
- 120 °C
- Charge temperature after intercooler
- 45 °C
- Cooling-air temperature
- 25 °C
Default result: Intercooler temperature effectiveness: 78.947 %.
Assumptions
- Use consistent units and measurements from the same operating point.
- Displayed example quantities demonstrate arithmetic and are not prescriptions.
Limitations
- Effectiveness is not pressure recovery. Readings must describe the same stabilized operating point.
Common mistakes
- Entering an outside dimension when the field requires a pitch, internal or effective dimension.
- Treating supplied rates, coefficients, quotes or appraisals as a live database.
- Effectiveness is not pressure recovery. Readings must describe the same stabilized operating point.
Sources and methodology
Method reviewed October 1, 2026. Formulas are implemented independently; references explain the dimensions, ratings or application requirements.
- NASA Glenn — gas equation of state ↗
Pressure, absolute temperature and ideal-gas density. Power extrapolation is a scenario, not a manufacturer-certified power law.
- NIST — SI conversion factors ↗
Declared mechanical horsepower, length, mass, volume and pressure unit conversions; dimensional calculations are derived independently.
Frequently asked questions
What does this intercooler efficiency result represent?
Compare the actual temperature reduction with the maximum reduction to the cooling medium.
Which application limits should I check?
Effectiveness is not pressure recovery. Readings must describe the same stabilized operating point.
Can I reuse the displayed example as a specification?
Use the example to understand the arithmetic. Replace all assumptions with measurements, applicable manufacturer specifications or current transaction quotes.