Formula and method
AFR = air mass / fuel mass, lambda = AFR / fuel-specific stoichiometric AFR.
AFR = air mass flow / fuel mass flow
Lambda = measured AFR / fuel-specific stoichiometric AFR
AFR from lambda = lambda × stoichiometric AFR
Understanding your inputs
- Measured air mass flow
- Enter g/s. Accepted input range: 0.000001–10000.
- Measured fuel mass flow
- Enter g/s. Accepted input range: 0.000001–10000.
- Fuel-specific stoichiometric AFR
- Enter air:fuel. Accepted input range: 0.000001–30.
- Lambda for companion conversion
- Enter ratio. Accepted input range: 0.000001–5.
Worked example
Use the displayed example: Measured air mass flow: 250 g/s; Measured fuel mass flow: 20 g/s; Fuel-specific stoichiometric AFR: 14.7 air:fuel; Lambda for companion conversion: 0.85 ratio. Measured air-fuel mass ratio is 12.500 air:fuel. Companion outputs use the same example inputs unless separately labelled.
Example inputs
- Measured air mass flow
- 250 g/s
- Measured fuel mass flow
- 20 g/s
- Fuel-specific stoichiometric AFR
- 14.7 air:fuel
- Lambda for companion conversion
- 0.85 ratio
Default result: Measured air-fuel mass ratio: 12.500 air:fuel.
Assumptions
- The example is Measured air mass flow: 250 g/s; Measured fuel mass flow: 20 g/s; Fuel-specific stoichiometric AFR: 14.7 air:fuel; Lambda for companion conversion: 0.85 ratio.
- Illustrative inputs are editable assumptions. A numerical result does not establish component compatibility or a measured vehicle rating.
Limitations
- Use synchronized mass flow measurements. The gasoline example of 14.7 is not universal for ethanol or other blends.
- Illustrative inputs are editable assumptions. A numerical result does not establish component compatibility or a measured vehicle rating.
Common mistakes
- Entering values in units different from the selected or displayed labels (g/s, g/s, air:fuel, ratio).
- No. The example represents a gasoline convention. Enter the fuel-specific value for the actual composition before converting lambda and AFR.
- Combining measurements taken at different operating points or temperatures.
Sources and methodology
Method reviewed October 1, 2026. Formulas are implemented independently; references explain the dimensions, ratings or application requirements.
- Holley EFI — installation and sizing reference ↗
Fuel injector sizing using horsepower, BSFC, count and duty cycle; square-root differential-pressure flow scaling. Density and reserves remain user inputs.
- NIST — SI conversion factors ↗
Declared mechanical horsepower, length, mass, volume and pressure unit conversions; dimensional calculations are derived independently.
Frequently asked questions
How does the air-fuel ratio calculation work?
AFR = air mass / fuel mass, lambda = AFR / fuel-specific stoichiometric AFR.
Is 14.7 the stoichiometric AFR for every fuel?
No. The example represents a gasoline convention. Enter the fuel-specific value for the actual composition before converting lambda and AFR.
What do the example values represent?
They demonstrate the method with editable inputs. Use synchronized mass flow measurements. The gasoline example of 14.7 is not universal for ethanol or other blends.
How should I handle an invalid input?
Enter finite values in the stated units and ranges. Empty required fields, zero denominators and inconsistent geometry hide the previous result and show an input error. Reset example restores the documented scenario.