Formula and method
Budget replenishment of all trip energy at the supplied tariff mix; stop count is an energy-equivalent count.
Cost = distance × battery use per mile / charging efficiency × weighted tariff + fees
Replenishment-equivalent stops = ceiling(trip battery energy / energy per stop)
Understanding your inputs
- Trip distance
- Enter mi. Accepted input range: 0.000001–1000000.
- Battery consumption
- Enter kWh/100 mi. Accepted input range: 0.000001–200.
- Charging efficiency
- Enter %. Accepted input range: 0.000001–100.
- Share of replenishment energy at public tariff
- Enter %. Accepted input range: 0–100.
- Home tariff
- Enter USD/kWh. Accepted input range: 0–10.
- Public tariff
- Enter USD/kWh. Accepted input range: 0–10.
- Total quoted trip session fees
- Enter USD. Accepted input range: 0–1000000000.
- Usable battery capacity
- Enter kWh. Accepted input range: 0.000001–1000000.
- Energy per stop as fraction of usable capacity
- Enter %. Accepted input range: 0.000001–100.
Worked example
Example inputs: Trip distance: 500 mi; Battery consumption: 30 kWh/100 mi; Charging efficiency: 90 %; Share of replenishment energy at public tariff: 60 %; Home tariff: 0.18 USD/kWh; Public tariff: 0.45 USD/kWh; Total quoted trip session fees: 5 USD; Usable battery capacity: 60 kWh; Energy per stop as fraction of usable capacity: 60 %. Electricity replenishment trip cost: 62.00 USD. Independent companion modules use their separately labelled inputs.
Example inputs
- Trip distance
- 500 mi
- Battery consumption
- 30 kWh/100 mi
- Charging efficiency
- 90 %
- Share of replenishment energy at public tariff
- 60 %
- Home tariff
- 0.18 USD/kWh
- Public tariff
- 0.45 USD/kWh
- Total quoted trip session fees
- 5 USD
- Usable battery capacity
- 60 kWh
- Energy per stop as fraction of usable capacity
- 60 %
Default result: Electricity replenishment trip cost: 62.00 USD.
Assumptions
- Use consistent units and measurements from the same operating point.
- Displayed example quantities demonstrate arithmetic and are not prescriptions.
Limitations
- The stop count does not subtract departure energy or plan charger locations. Detours, queueing, curve taper and arrival reserve need a route plan.
Common mistakes
- Entering an outside dimension when the field requires a pitch, internal or effective dimension.
- Treating supplied rates, coefficients, quotes or appraisals as a live database.
- The stop count does not subtract departure energy or plan charger locations. Detours, queueing, curve taper and arrival reserve need a route plan.
Sources and methodology
Method reviewed October 1, 2026. Formulas are implemented independently; references explain the dimensions, ratings or application requirements.
- US EPA — automotive efficiency reporting ↗
MPGe compares energy with a gasoline-equivalent energy quantity; this implementation explicitly rounds that quantity to 33.7 kWh. Grid/battery energy boundaries, prices and loss fractions are declared inputs.
- NIST — SI conversion factors ↗
Declared mechanical horsepower, length, mass, volume and pressure unit conversions; dimensional calculations are derived independently.
Frequently asked questions
What does this ev trip cost result represent?
Budget replenishment of all trip energy at the supplied tariff mix; stop count is an energy-equivalent count.
Which application limits should I check?
The stop count does not subtract departure energy or plan charger locations. Detours, queueing, curve taper and arrival reserve need a route plan.
Can I reuse the displayed example as a specification?
Use the example to understand the arithmetic. Replace all assumptions with measurements, applicable manufacturer specifications or current transaction quotes.