Formula and method
Use the usable-capacity SOC boundary and battery consumption, excluding grid charging losses.
Usable capacity = nominal × usable fraction
Range = usable capacity × (SOC − reserve)/100 / battery kWh per mile
Understanding your inputs
- Nominal battery capacity
- Enter kWh. Accepted input range: 0.000001–1000000.
- Usable fraction of nominal capacity
- Enter %. Accepted input range: 0.000001–100.
- Current SOC of usable capacity
- Enter %. Accepted input range: 0–100.
- Ending SOC reserve
- Enter %. Accepted input range: 0–100.
- Battery consumption
- Enter kWh/100 mi. Accepted input range: 0.000001–200.
Worked example
Example inputs: Nominal battery capacity: 75 kWh; Usable fraction of nominal capacity: 80 %; Current SOC of usable capacity: 80 %; Ending SOC reserve: 10 %; Battery consumption: 30 kWh/100 mi. Range before supplied reserve: 140.000 mi. Independent companion modules use their separately labelled inputs.
Example inputs
- Nominal battery capacity
- 75 kWh
- Usable fraction of nominal capacity
- 80 %
- Current SOC of usable capacity
- 80 %
- Ending SOC reserve
- 10 %
- Battery consumption
- 30 kWh/100 mi
Default result: Range before supplied reserve: 140.000 mi.
Assumptions
- Use consistent units and measurements from the same operating point.
- Displayed example quantities demonstrate arithmetic and are not prescriptions.
Limitations
- Weather, speed, elevation, aging and actual BMS reserve affect range. Nominal capacity cannot be used as usable capacity without a verified fraction.
Common mistakes
- Entering an outside dimension when the field requires a pitch, internal or effective dimension.
- Treating supplied rates, coefficients, quotes or appraisals as a live database.
- Weather, speed, elevation, aging and actual BMS reserve affect range. Nominal capacity cannot be used as usable capacity without a verified fraction.
Sources and methodology
Method reviewed October 1, 2026. Formulas are implemented independently; references explain the dimensions, ratings or application requirements.
- US EPA — automotive efficiency reporting ↗
MPGe compares energy with a gasoline-equivalent energy quantity; this implementation explicitly rounds that quantity to 33.7 kWh. Grid/battery energy boundaries, prices and loss fractions are declared inputs.
- NIST — SI conversion factors ↗
Declared mechanical horsepower, length, mass, volume and pressure unit conversions; dimensional calculations are derived independently.
Frequently asked questions
What does this ev range result represent?
Use the usable-capacity SOC boundary and battery consumption, excluding grid charging losses.
Which application limits should I check?
Weather, speed, elevation, aging and actual BMS reserve affect range. Nominal capacity cannot be used as usable capacity without a verified fraction.
Can I reuse the displayed example as a specification?
Use the example to understand the arithmetic. Replace all assumptions with measurements, applicable manufacturer specifications or current transaction quotes.