Formula and method
Constrain supply power by the vehicle input limit, then apply supplied loss and average/taper factors.
AC power = V × A × power factor × phase multiplier
Time = battery capacity × SOC change / (efficiency × constrained AC power × average-power fraction)
Understanding your inputs
- Usable battery capacity
- Enter kWh. Accepted input range: 0.000001–1000000.
- Starting SOC
- Enter %. Accepted input range: 0–100.
- Target SOC
- Enter %. Accepted input range: 0–100.
- AC supply voltage
- Enter V. Accepted input range: 0.000001–1000.
- AC supply current
- Enter A. Accepted input range: 0.000001–1000.
- AC phase configuration
- Single phase or Three phase — line voltage
- Power factor
- Enter ratio. Accepted input range: 0.000001–1.
- Vehicle AC input power limit
- Enter kW. Accepted input range: 0.000001–100.
- Grid-to-battery efficiency
- Enter %. Accepted input range: 0.000001–100.
- Average power / constrained power
- Enter %. Accepted input range: 0.000001–100.
Worked example
Example inputs: Usable battery capacity: 60 kWh; Starting SOC: 20 %; Target SOC: 80 %; AC supply voltage: 240 V; AC supply current: 32 A; AC phase configuration: Single phase; Power factor: 1 ratio; Vehicle AC input power limit: 7.2 kW; Grid-to-battery efficiency: 90 %; Average power / constrained power: 85 %. Charge time with supplied average-power factor: 6.536 hours. Independent companion modules use their separately labelled inputs.
Example inputs
- Usable battery capacity
- 60 kWh
- Starting SOC
- 20 %
- Target SOC
- 80 %
- AC supply voltage
- 240 V
- AC supply current
- 32 A
- AC phase configuration
- Single phase
- Power factor
- 1 ratio
- Vehicle AC input power limit
- 7.2 kW
- Grid-to-battery efficiency
- 90 %
- Average power / constrained power
- 85 %
Default result: Charge time with supplied average-power factor: 6.536 hours.
Assumptions
- Use consistent units and measurements from the same operating point.
- Displayed example quantities demonstrate arithmetic and are not prescriptions.
Limitations
- SOC, temperature and taper vary. This AC model is not a DC fast-charge curve or guaranteed charge time.
Common mistakes
- Entering an outside dimension when the field requires a pitch, internal or effective dimension.
- Treating supplied rates, coefficients, quotes or appraisals as a live database.
- SOC, temperature and taper vary. This AC model is not a DC fast-charge curve or guaranteed charge time.
Sources and methodology
Method reviewed October 1, 2026. Formulas are implemented independently; references explain the dimensions, ratings or application requirements.
- US EPA — automotive efficiency reporting ↗
MPGe compares energy with a gasoline-equivalent energy quantity; this implementation explicitly rounds that quantity to 33.7 kWh. Grid/battery energy boundaries, prices and loss fractions are declared inputs.
- NIST — SI conversion factors ↗
Declared mechanical horsepower, length, mass, volume and pressure unit conversions; dimensional calculations are derived independently.
Frequently asked questions
What does this ev charging time result represent?
Constrain supply power by the vehicle input limit, then apply supplied loss and average/taper factors.
Which application limits should I check?
SOC, temperature and taper vary. This AC model is not a DC fast-charge curve or guaranteed charge time.
Can I reuse the displayed example as a specification?
Use the example to understand the arithmetic. Replace all assumptions with measurements, applicable manufacturer specifications or current transaction quotes.