Formula and method
Distinguish measured gauge boost from absolute pressure ratio; the supercharger module uses a separately supplied ratio.
Gauge boost = manifold absolute − ambient absolute
Scenario boost = ambient × (PR − 1)
Understanding your inputs
- Measured manifold absolute pressure
- Enter psia. Accepted input range: 0.000001–150.
- Measured ambient absolute pressure
- Enter psia. Accepted input range: 0.000001–30.
- Supercharger inlet-to-outlet pressure ratio scenario
- Enter ratio. Accepted input range: 0.000001–10.
Worked example
Example inputs: Measured manifold absolute pressure: 21.7 psia; Measured ambient absolute pressure: 14.7 psia; Supercharger inlet-to-outlet pressure ratio scenario: 1.5 ratio. Manifold gauge boost: 7.000 psi. Independent companion modules use their separately labelled inputs.
Example inputs
- Measured manifold absolute pressure
- 21.7 psia
- Measured ambient absolute pressure
- 14.7 psia
- Supercharger inlet-to-outlet pressure ratio scenario
- 1.5 ratio
Default result: Manifold gauge boost: 7.000 psi.
Assumptions
- Use consistent units and measurements from the same operating point.
- Displayed example quantities demonstrate arithmetic and are not prescriptions.
Limitations
- Pulley speed alone cannot predict supercharger boost. Flow maps, leakage, temperature, engine demand and pressure losses matter.
Common mistakes
- Entering an outside dimension when the field requires a pitch, internal or effective dimension.
- Treating supplied rates, coefficients, quotes or appraisals as a live database.
- Pulley speed alone cannot predict supercharger boost. Flow maps, leakage, temperature, engine demand and pressure losses matter.
Sources and methodology
Method reviewed October 1, 2026. Formulas are implemented independently; references explain the dimensions, ratings or application requirements.
- Garrett Motion — compressor map methods ↗
Compressor mass flow and absolute-pressure ratio, inlet/outlet losses, and use of maps across the operating range. No turbo model is selected from a single point.
- NIST — SI conversion factors ↗
Declared mechanical horsepower, length, mass, volume and pressure unit conversions; dimensional calculations are derived independently.
Frequently asked questions
What does this boost result represent?
Distinguish measured gauge boost from absolute pressure ratio; the supercharger module uses a separately supplied ratio.
Which application limits should I check?
Pulley speed alone cannot predict supercharger boost. Flow maps, leakage, temperature, engine demand and pressure losses matter.
Can I reuse the displayed example as a specification?
Use the example to understand the arithmetic. Replace all assumptions with measurements, applicable manufacturer specifications or current transaction quotes.