Formula and method
Convert MAF mass flow to lb/min, then use fuel flow = airflow / AFR and horsepower = hourly fuel mass / BSFC.
Air (lb/min) = MAF (g/s) × 60 / 453.59237
HP = air (lb/min) × 60 / (AFR × BSFC)
Understanding your inputs
- Measured mass airflow
- Enter g/s. Accepted input range: 0.000001–10000.
- Operating air-fuel mass ratio
- Enter air:fuel. Accepted input range: 0.000001–40.
- Assumed BSFC
- Enter lb/(hp·h). Accepted input range: 0.000001–5.
Worked example
Use the displayed example: Measured mass airflow: 250 g/s; Operating air-fuel mass ratio: 12 air:fuel; Assumed BSFC: 0.5 lb/(hp·h). Power implied by airflow and fuel assumptions is 330.69 hp. Companion outputs use the same example inputs unless separately labelled.
Example inputs
- Measured mass airflow
- 250 g/s
- Operating air-fuel mass ratio
- 12 air:fuel
- Assumed BSFC
- 0.5 lb/(hp·h)
Default result: Power implied by airflow and fuel assumptions: 330.69 hp.
Assumptions
- The example is Measured mass airflow: 250 g/s; Operating air-fuel mass ratio: 12 air:fuel; Assumed BSFC: 0.5 lb/(hp·h).
- Illustrative inputs are editable assumptions. A numerical result does not establish component compatibility or a measured vehicle rating.
Limitations
- MAF readings, AFR and BSFC must describe the same operating point; airflow alone does not uniquely determine horsepower.
- Illustrative inputs are editable assumptions. A numerical result does not establish component compatibility or a measured vehicle rating.
Common mistakes
- Entering values in units different from the selected or displayed labels (g/s, air:fuel, lb/(hp·h)).
- Treating a dimensional or empirical estimate as an engine rating or component compatibility check.
- Combining measurements taken at different operating points or temperatures.
Sources and methodology
Method reviewed October 1, 2026. Formulas are implemented independently; references explain the dimensions, ratings or application requirements.
- Holley EFI — installation and sizing reference ↗
Fuel injector sizing using horsepower, BSFC, count and duty cycle; square-root differential-pressure flow scaling. Density and reserves remain user inputs.
- NIST — SI conversion factors ↗
Declared mechanical horsepower, length, mass, volume and pressure unit conversions; dimensional calculations are derived independently.
Frequently asked questions
How does the maf to hp calculation work?
Convert MAF mass flow to lb/min, then use fuel flow = airflow / AFR and horsepower = hourly fuel mass / BSFC.
What do the example values represent?
They demonstrate the method with editable inputs. MAF readings, AFR and BSFC must describe the same operating point; airflow alone does not uniquely determine horsepower.
How should I handle an invalid input?
Enter finite values in the stated units and ranges. Empty required fields, zero denominators and inconsistent geometry hide the previous result and show an input error. Reset example restores the documented scenario.