Formula and method
Hourly fuel flow divided by BSFC gives shaft power.
HP = airflow (lb/min) × 60 / (AFR × BSFC)
Understanding your inputs
- Airflow
- Enter lb/min. Accepted input range: 0.000001–10000.
- Operating air-fuel mass ratio
- Enter air:fuel. Accepted input range: 0.000001–40.
- Assumed BSFC
- Enter lb/(hp·h). Accepted input range: 0.000001–5.
Worked example
Use the displayed example: Airflow: 40 lb/min; Operating air-fuel mass ratio: 12 air:fuel; Assumed BSFC: 0.5 lb/(hp·h). Power implied by air and fuel flow is 400.00 hp. Companion outputs use the same example inputs unless separately labelled.
Example inputs
- Airflow
- 40 lb/min
- Operating air-fuel mass ratio
- 12 air:fuel
- Assumed BSFC
- 0.5 lb/(hp·h)
Default result: Power implied by air and fuel flow: 400.00 hp.
Assumptions
- The example is Airflow: 40 lb/min; Operating air-fuel mass ratio: 12 air:fuel; Assumed BSFC: 0.5 lb/(hp·h).
- Illustrative inputs are editable assumptions. A numerical result does not establish component compatibility or a measured vehicle rating.
Limitations
- Airflow, AFR and BSFC must represent the same operating point.
- Illustrative inputs are editable assumptions. A numerical result does not establish component compatibility or a measured vehicle rating.
Common mistakes
- Entering values in units different from the selected or displayed labels (lb/min, air:fuel, lb/(hp·h)).
- Treating a dimensional or empirical estimate as an engine rating or component compatibility check.
- Combining measurements taken at different operating points or temperatures.
Sources and methodology
Method reviewed October 1, 2026. Formulas are implemented independently; references explain the dimensions, ratings or application requirements.
- Holley EFI — installation and sizing reference ↗
Fuel injector sizing using horsepower, BSFC, count and duty cycle; square-root differential-pressure flow scaling. Density and reserves remain user inputs.
- NIST — SI conversion factors ↗
Declared mechanical horsepower, length, mass, volume and pressure unit conversions; dimensional calculations are derived independently.
Frequently asked questions
How does the airflow to horsepower calculation work?
Hourly fuel flow divided by BSFC gives shaft power.
What do the example values represent?
They demonstrate the method with editable inputs. Airflow, AFR and BSFC must represent the same operating point.
How should I handle an invalid input?
Enter finite values in the stated units and ranges. Empty required fields, zero denominators and inconsistent geometry hide the previous result and show an input error. Reset example restores the documented scenario.