Formula and method
Estimate discharge time with a supplied rate-effect exponent; starter demand and warranty proration have separate inputs.
Runtime = 20 × (C20/(20 × current))^Peukert × usable fraction
Starter A = output watts/(loaded volts × efficiency)
Proration = price × max(0, 1 − age/warranty duration)
Understanding your inputs
- Battery capacity at 20-hour rate
- Enter Ah. Accepted input range: 0.000001–1000.
- Continuous accessory draw
- Enter A. Accepted input range: 0.000001–1000.
- Allowed usable fraction
- Enter %. Accepted input range: 0.000001–100.
- Supplied Peukert exponent
- Enter exponent. Accepted input range: 0.000001–1.5.
- Separate electrical starter output demand
- Enter W. Accepted input range: 0.000001–20000.
- Starter supply voltage under load
- Enter V. Accepted input range: 0.000001–100.
- Starter electrical-to-output efficiency
- Enter %. Accepted input range: 0.000001–100.
- Battery warranty price basis
- Enter USD. Accepted input range: 0–1000000000.
- Prorated warranty duration
- Enter months. Accepted input range: 0.000001–120.
- Elapsed prorated warranty age
- Enter months. Accepted input range: 0–240.
Worked example
Example inputs: Battery capacity at 20-hour rate: 60 Ah; Continuous accessory draw: 10 A; Allowed usable fraction: 50 %; Supplied Peukert exponent: 1.1 exponent; Separate electrical starter output demand: 2000 W; Starter supply voltage under load: 12 V; Starter electrical-to-output efficiency: 80 %; Battery warranty price basis: 150 USD; Prorated warranty duration: 36 months; Elapsed prorated warranty age: 12 months. Discharge-runtime scenario: 2.660 hours. Independent companion modules use their separately labelled inputs.
Example inputs
- Battery capacity at 20-hour rate
- 60 Ah
- Continuous accessory draw
- 10 A
- Allowed usable fraction
- 50 %
- Supplied Peukert exponent
- 1.1 exponent
- Separate electrical starter output demand
- 2000 W
- Starter supply voltage under load
- 12 V
- Starter electrical-to-output efficiency
- 80 %
- Battery warranty price basis
- 150 USD
- Prorated warranty duration
- 36 months
- Elapsed prorated warranty age
- 12 months
Default result: Discharge-runtime scenario: 2.660 hours.
Assumptions
- Use consistent units and measurements from the same operating point.
- Displayed example quantities demonstrate arithmetic and are not prescriptions.
Limitations
- This cannot predict calendar replacement life or warranty entitlement. Actual starting tests, battery condition, temperature and the written warranty control.
Common mistakes
- Entering an outside dimension when the field requires a pitch, internal or effective dimension.
- Treating supplied rates, coefficients, quotes or appraisals as a live database.
- This cannot predict calendar replacement life or warranty entitlement. Actual starting tests, battery condition, temperature and the written warranty control.
Sources and methodology
Method reviewed October 1, 2026. Formulas are implemented independently; references explain the dimensions, ratings or application requirements.
- Trojan Battery — AGM maintenance and temperature compensation ↗
Chemistry-specific charging voltage and temperature compensation. Ah, discharge-rate runtime and reserve-test arithmetic are separately declared models, not universal CCA conversions.
- NIST — SI conversion factors ↗
Declared mechanical horsepower, length, mass, volume and pressure unit conversions; dimensional calculations are derived independently.
Frequently asked questions
What does this car battery life result represent?
Estimate discharge time with a supplied rate-effect exponent; starter demand and warranty proration have separate inputs.
Which application limits should I check?
This cannot predict calendar replacement life or warranty entitlement. Actual starting tests, battery condition, temperature and the written warranty control.
Can I reuse the displayed example as a specification?
Use the example to understand the arithmetic. Replace all assumptions with measurements, applicable manufacturer specifications or current transaction quotes.