Formula and method
Integrate the specified constant 25-A discharge over the reserve-test interval.
Ah at 25-A reserve test = 25 × reserve minutes / 60
Understanding your inputs
- Constant-25A conversion direction
- Reserve minutes → delivered Ah at 25 A or Delivered Ah at 25 A → reserve minutes
- Reserve capacity at the specified test endpoint
- Enter min. Accepted input range: 0.000001–10000.
- Delivered capacity under the same 25-A test
- Enter Ah. Accepted input range: 0.000001–1000.
Worked example
Example inputs: Constant-25A conversion direction: Reserve minutes → delivered Ah at 25 A; Reserve capacity at the specified test endpoint: 120 min. Capacity delivered at constant 25 A: 50.000 Ah. Independent companion modules use their separately labelled inputs.
Example inputs
- Constant-25A conversion direction
- Reserve minutes → delivered Ah at 25 A
- Reserve capacity at the specified test endpoint
- 120 min
Default result: Capacity delivered at constant 25 A: 50.000 Ah.
Assumptions
- Use consistent units and measurements from the same operating point.
- Displayed example quantities demonstrate arithmetic and are not prescriptions.
Limitations
- This is delivered Ah at the reserve test rate and endpoint, not necessarily the battery’s C20 rating. Temperature, endpoint and discharge-rate capacity effects must match.
Common mistakes
- Entering an outside dimension when the field requires a pitch, internal or effective dimension.
- Treating supplied rates, coefficients, quotes or appraisals as a live database.
- This is delivered Ah at the reserve test rate and endpoint, not necessarily the battery’s C20 rating. Temperature, endpoint and discharge-rate capacity effects must match.
Sources and methodology
Method reviewed October 1, 2026. Formulas are implemented independently; references explain the dimensions, ratings or application requirements.
- Trojan Battery — AGM maintenance and temperature compensation ↗
Chemistry-specific charging voltage and temperature compensation. Ah, discharge-rate runtime and reserve-test arithmetic are separately declared models, not universal CCA conversions.
- NIST — SI conversion factors ↗
Declared mechanical horsepower, length, mass, volume and pressure unit conversions; dimensional calculations are derived independently.
Frequently asked questions
What does this battery reserve capacity result represent?
Integrate the specified constant 25-A discharge over the reserve-test interval.
Which application limits should I check?
This is delivered Ah at the reserve test rate and endpoint, not necessarily the battery’s C20 rating. Temperature, endpoint and discharge-rate capacity effects must match.
Can I reuse the displayed example as a specification?
Use the example to understand the arithmetic. Replace all assumptions with measurements, applicable manufacturer specifications or current transaction quotes.