Formula and method
Include outbound and return conductors with the same entered area.
Loop voltage drop = 2 × one-way length × copper resistivity × amperes / conductor area
Understanding your inputs
- Circuit current
- Enter A. Accepted input range: 0.000001–1000000.
- ONE-WAY copper run
- Enter ft. Accepted input range: 0.000001–1000000.
- AWG numeric code (0=1/0; −1=2/0; −3=4/0)
- Enter AWG code. Accepted input range: -3–30.
- Copper conductor temperature
- Enter °C. Accepted input range: -20–200.
- Supply voltage
- Enter V. Accepted input range: 0.000001–1000000.
Worked example
Example inputs: Circuit current: 50 A; ONE-WAY copper run: 15 ft; AWG numeric code (0=1/0; −1=2/0; −3=4/0): 4 AWG code; Copper conductor temperature: 60 °C; Supply voltage: 13.8 V. Complete-loop copper voltage drop: 0.431 V. Independent companion modules use their separately labelled inputs.
Example inputs
- Circuit current
- 50 A
- ONE-WAY copper run
- 15 ft
- AWG numeric code (0=1/0; −1=2/0; −3=4/0)
- 4 AWG code
- Copper conductor temperature
- 60 °C
- Supply voltage
- 13.8 V
Default result: Complete-loop copper voltage drop: 0.431 V.
Assumptions
- Use consistent units and measurements from the same operating point.
- Displayed example quantities demonstrate arithmetic and are not prescriptions.
Limitations
- Connections and chassis-return resistance are excluded. Negative load voltage flags an unusable idealized circuit; ampacity requires separate verification.
Common mistakes
- Entering an outside dimension when the field requires a pitch, internal or effective dimension.
- Treating supplied rates, coefficients, quotes or appraisals as a live database.
- Connections and chassis-return resistance are excluded. Negative load voltage flags an unusable idealized circuit; ampacity requires separate verification.
Sources and methodology
Method reviewed October 1, 2026. Formulas are implemented independently; references explain the dimensions, ratings or application requirements.
- Rockford Fosgate — amplifier electrical requirements ↗
Manufacturer-specific amplifier supply, fuse and wiring requirements. Ideal copper voltage-drop and AWG geometry do not supply thermal ampacity.
- NIST — SI conversion factors ↗
Declared mechanical horsepower, length, mass, volume and pressure unit conversions; dimensional calculations are derived independently.
Frequently asked questions
What does this automotive voltage drop result represent?
Include outbound and return conductors with the same entered area.
Which application limits should I check?
Connections and chassis-return resistance are excluded. Negative load voltage flags an unusable idealized circuit; ampacity requires separate verification.
Can I reuse the displayed example as a specification?
Use the example to understand the arithmetic. Replace all assumptions with measurements, applicable manufacturer specifications or current transaction quotes.