Formula and method
Keep calendar time and equivalent full cycles distinct in an explicitly supplied compounded-loss scenario.
SOH = initial SOH × (1 − calendar loss)^years × (1 − cycle loss)^(cycles/1000)
Understanding your inputs
- Starting measured state of health
- Enter %. Accepted input range: 0.000001–100.
- Assumed annual calendar loss
- Enter %. Accepted input range: 0–30.
- Elapsed time
- Enter years. Accepted input range: 0–30.
- Equivalent full cycles
- Enter cycles. Accepted input range: 0–10000.
- Assumed loss per 1,000 full cycles
- Enter %. Accepted input range: 0–50.
- Original usable capacity
- Enter kWh. Accepted input range: 0.000001–1000000.
Worked example
Example inputs: Starting measured state of health: 100 %; Assumed annual calendar loss: 2 %; Elapsed time: 5 years; Equivalent full cycles: 500 cycles; Assumed loss per 1,000 full cycles: 5 %; Original usable capacity: 60 kWh. Compounded battery-health scenario: 88.103 %. Independent companion modules use their separately labelled inputs.
Example inputs
- Starting measured state of health
- 100 %
- Assumed annual calendar loss
- 2 %
- Elapsed time
- 5 years
- Equivalent full cycles
- 500 cycles
- Assumed loss per 1,000 full cycles
- 5 %
- Original usable capacity
- 60 kWh
Default result: Compounded battery-health scenario: 88.103 %.
Assumptions
- Use consistent units and measurements from the same operating point.
- Displayed example quantities demonstrate arithmetic and are not prescriptions.
Limitations
- Rates are user assumptions, not an OEM life model. Temperature, SOC exposure, chemistry, fast charging and warranty definitions can dominate actual aging.
Common mistakes
- Entering an outside dimension when the field requires a pitch, internal or effective dimension.
- Treating supplied rates, coefficients, quotes or appraisals as a live database.
- Rates are user assumptions, not an OEM life model. Temperature, SOC exposure, chemistry, fast charging and warranty definitions can dominate actual aging.
Sources and methodology
Method reviewed October 1, 2026. Formulas are implemented independently; references explain the dimensions, ratings or application requirements.
- US EPA — automotive efficiency reporting ↗
MPGe compares energy with a gasoline-equivalent energy quantity; this implementation explicitly rounds that quantity to 33.7 kWh. Grid/battery energy boundaries, prices and loss fractions are declared inputs.
- NIST — SI conversion factors ↗
Declared mechanical horsepower, length, mass, volume and pressure unit conversions; dimensional calculations are derived independently.
Frequently asked questions
What does this ev battery degradation result represent?
Keep calendar time and equivalent full cycles distinct in an explicitly supplied compounded-loss scenario.
Which application limits should I check?
Rates are user assumptions, not an OEM life model. Temperature, SOC exposure, chemistry, fast charging and warranty definitions can dominate actual aging.
Can I reuse the displayed example as a specification?
Use the example to understand the arithmetic. Replace all assumptions with measurements, applicable manufacturer specifications or current transaction quotes.