COOLING, FLUIDS & MAINTENANCE / WORKSHOP TOOL

Radiator Capacity Calculator

Use measured heat balance and separately supplied internal fluid geometry.

Measured coolant-side heat rejection36.000 kWDetails ↓
01

Your inputs

EDIT TO RECALCULATE
kg/s

J/(kg·K)

°C

count

mm²

mm

L

02

Your result

Measured coolant-side heat rejection
36.000kW
Radiator fluid-volume geometry
1.980 L

Use measured heat balance and separately supplied internal fluid geometry.

  • This does not select radiator dimensions or predict air-side performance. Tube cross-section is actual internal area, not an outside dimension.
  • Example values demonstrate arithmetic. Use measurements, component specifications and applicable requirements for your actual vehicle.

Formula and method

Use measured heat balance and separately supplied internal fluid geometry.

Heat kW = mass flow × specific heat × coolant temperature drop / 1000

Fluid L = tube count × internal area × fluid path / 10^6 + tank volume

Understanding your inputs

Measured coolant mass flow
Enter kg/s. Accepted input range: 0.000001–1000000.
Coolant specific heat at operating conditions
Enter J/(kg·K). Accepted input range: 0.000001–10000.
Measured coolant temperature drop
Enter °C. Accepted input range: 0.000001–200.
Fluid tube count
Enter count, as a whole number. Accepted input range: 1–10000.
Actual internal fluid area per tube
Enter mm². Accepted input range: 0.000001–1000000.
Fluid path per tube
Enter mm. Accepted input range: 0.000001–1000000.
Combined tank fluid volume
Enter L. Accepted input range: 0–100.

Worked example

Example inputs: Measured coolant mass flow: 1 kg/s; Coolant specific heat at operating conditions: 3600 J/(kg·K); Measured coolant temperature drop: 10 °C; Fluid tube count: 40 count; Actual internal fluid area per tube: 20 mm²; Fluid path per tube: 600 mm; Combined tank fluid volume: 1.5 L. Measured coolant-side heat rejection: 36.000 kW. Independent companion modules use their separately labelled inputs.

Example inputs
Measured coolant mass flow
1 kg/s
Coolant specific heat at operating conditions
3600 J/(kg·K)
Measured coolant temperature drop
10 °C
Fluid tube count
40 count
Actual internal fluid area per tube
20 mm²
Fluid path per tube
600 mm
Combined tank fluid volume
1.5 L

Default result: Measured coolant-side heat rejection: 36.000 kW.

Assumptions

  • Use consistent units and measurements from the same operating point.
  • Displayed example quantities demonstrate arithmetic and are not prescriptions.

Limitations

  • This does not select radiator dimensions or predict air-side performance. Tube cross-section is actual internal area, not an outside dimension.

Common mistakes

  • Entering an outside dimension when the field requires a pitch, internal or effective dimension.
  • Treating supplied rates, coefficients, quotes or appraisals as a live database.
  • This does not select radiator dimensions or predict air-side performance. Tube cross-section is actual internal area, not an outside dimension.

Sources and methodology

Method reviewed October 1, 2026. Formulas are implemented independently; references explain the dimensions, ratings or application requirements.

Frequently asked questions

What does this radiator capacity result represent?

Use measured heat balance and separately supplied internal fluid geometry.

Which application limits should I check?

This does not select radiator dimensions or predict air-side performance. Tube cross-section is actual internal area, not an outside dimension.

Can I reuse the displayed example as a specification?

Use the example to understand the arithmetic. Replace all assumptions with measurements, applicable manufacturer specifications or current transaction quotes.