Formula and method
Model one drain of a fully mixed system followed by equal-volume replacement.
Replacement volume = system volume × (target − current)/(replacement concentration − current)
Understanding your inputs
- Full cooling-system volume
- Enter L. Accepted input range: 0.000001–1000000.
- Existing antifreeze concentration
- Enter %. Accepted input range: 0–100.
- Target concentration
- Enter %. Accepted input range: 0–100.
- Replacement-fluid concentrate fraction
- Enter %. Accepted input range: 0–100.
Worked example
Example inputs: Full cooling-system volume: 10 L; Existing antifreeze concentration: 30 %; Target concentration: 50 %; Replacement-fluid concentrate fraction: 100 %. Drain and replace volume: 2.857 L. Independent companion modules use their separately labelled inputs.
Example inputs
- Full cooling-system volume
- 10 L
- Existing antifreeze concentration
- 30 %
- Target concentration
- 50 %
- Replacement-fluid concentrate fraction
- 100 %
Default result: Drain and replace volume: 2.857 L.
Assumptions
- Use consistent units and measurements from the same operating point.
- Displayed example quantities demonstrate arithmetic and are not prescriptions.
Limitations
- Use compatible manufacturer-approved coolant. This computes mixture concentration, not freeze/boil protection or service suitability.
Common mistakes
- Entering an outside dimension when the field requires a pitch, internal or effective dimension.
- Treating supplied rates, coefficients, quotes or appraisals as a live database.
- Use compatible manufacturer-approved coolant. This computes mixture concentration, not freeze/boil protection or service suitability.
Sources and methodology
Method reviewed October 1, 2026. Formulas are implemented independently; references explain the dimensions, ratings or application requirements.
- NIST — SI conversion factors ↗
Declared mechanical horsepower, length, mass, volume and pressure unit conversions; dimensional calculations are derived independently.
Frequently asked questions
What does this coolant ratio result represent?
Model one drain of a fully mixed system followed by equal-volume replacement.
Which application limits should I check?
Use compatible manufacturer-approved coolant. This computes mixture concentration, not freeze/boil protection or service suitability.
Can I reuse the displayed example as a specification?
Use the example to understand the arithmetic. Replace all assumptions with measurements, applicable manufacturer specifications or current transaction quotes.