Formula and method
Estimate quasistatic resistance and compare it with an ideal constant-drum-torque layer model.
Resistance = weight × (sin(slope) + Crr cos(slope)) + additional resistance
Required pull = resistance × allowance
Ideal layer capability = first-layer pull × first-layer radius / selected-layer radius
Understanding your inputs
- Recovery vehicle weight
- Enter lb. Accepted input range: 0.000001–1000000.
- Recovery slope
- Enter degrees. Accepted input range: 0–75.
- Supplied rolling resistance coefficient
- Enter coefficient. Accepted input range: 0–1.
- Additional measured/expert-assessed resistance
- Enter lbf. Accepted input range: 0–100000.
- Supplied design allowance multiplier
- Enter ratio. Accepted input range: 0.000001–10.
- Manufacturer first-layer line pull
- Enter lbf. Accepted input range: 0.000001–1000000.
- Bare drum radius
- Enter in. Accepted input range: 0.000001–20.
- Cable diameter
- Enter in. Accepted input range: 0.000001–2.
- Cable layer, first layer = 1
- Enter count, as a whole number. Accepted input range: 1–20.
Worked example
Example inputs: Recovery vehicle weight: 5000 lb; Recovery slope: 15 degrees; Supplied rolling resistance coefficient: 0.05 coefficient; Additional measured/expert-assessed resistance: 500 lbf; Supplied design allowance multiplier: 1.5 ratio; Manufacturer first-layer line pull: 10000 lbf; Bare drum radius: 2 in; Cable diameter: 0.375 in; Cable layer, first layer = 1: 3 count. Required line-pull allowance scenario: 3,053.365 lbf. Independent companion modules use their separately labelled inputs.
Example inputs
- Recovery vehicle weight
- 5000 lb
- Recovery slope
- 15 degrees
- Supplied rolling resistance coefficient
- 0.05 coefficient
- Additional measured/expert-assessed resistance
- 500 lbf
- Supplied design allowance multiplier
- 1.5 ratio
- Manufacturer first-layer line pull
- 10000 lbf
- Bare drum radius
- 2 in
- Cable diameter
- 0.375 in
- Cable layer, first layer = 1
- 3 count
Default result: Required line-pull allowance scenario: 3,053.365 lbf.
Assumptions
- Use consistent units and measurements from the same operating point.
- Displayed example quantities demonstrate arithmetic and are not prescriptions.
Limitations
- This does not certify a recovery setup. Drum rating, duty cycle, line/anchor ratings, shock loads, bog suction and manufacturer layer data can dominate.
Common mistakes
- Entering an outside dimension when the field requires a pitch, internal or effective dimension.
- Treating supplied rates, coefficients, quotes or appraisals as a live database.
- This does not certify a recovery setup. Drum rating, duty cycle, line/anchor ratings, shock loads, bog suction and manufacturer layer data can dominate.
Sources and methodology
Method reviewed October 1, 2026. Formulas are implemented independently; references explain the dimensions, ratings or application requirements.
- Ford — vehicle-specific towing guidance ↗
Exact vehicle configuration, manufacturer gross/combination/axle/hitch ratings and measured loading are required. Static hitch, offtracking and dimensional scenarios are derived separately.
- NIST — SI conversion factors ↗
Declared mechanical horsepower, length, mass, volume and pressure unit conversions; dimensional calculations are derived independently.
Frequently asked questions
What does this winch size result represent?
Estimate quasistatic resistance and compare it with an ideal constant-drum-torque layer model.
Which application limits should I check?
This does not certify a recovery setup. Drum rating, duty cycle, line/anchor ratings, shock loads, bog suction and manufacturer layer data can dominate.
Can I reuse the displayed example as a specification?
Use the example to understand the arithmetic. Replace all assumptions with measurements, applicable manufacturer specifications or current transaction quotes.