Formula and method
Divide pump RPM by the square root of pump torque in the declared unit system.
K-factor = pump RPM / √(pump torque); torque units must be declared
Understanding your inputs
- Converter pump speed
- Enter rpm. Accepted input range: 0.000001–50000.
- Converter pump input torque
- Enter lb·ft. Accepted input range: 0.000001–100000.
Worked example
Use the displayed example: Converter pump speed: 4000 rpm; Converter pump input torque: 300 lb·ft. Converter K-factor is 230.94 rpm/√(lb·ft). Companion outputs use the same example inputs unless separately labelled.
Example inputs
- Converter pump speed
- 4000 rpm
- Converter pump input torque
- 300 lb·ft
Default result: Converter K-factor: 230.94 rpm/√(lb·ft).
Assumptions
- The example is Converter pump speed: 4000 rpm; Converter pump input torque: 300 lb·ft.
- Illustrative inputs are editable assumptions. A numerical result does not establish component compatibility or a measured vehicle rating.
Limitations
- K-factor carries units and varies across converter speed ratios. Do not compare numerical factors from different torque units.
- Illustrative inputs are editable assumptions. A numerical result does not establish component compatibility or a measured vehicle rating.
Common mistakes
- Entering values in units different from the selected or displayed labels (rpm, lb·ft).
- No. K-factor is dimensioned. The numerical values in rpm/√(lb·ft) and rpm/√(N·m) differ.
- Combining measurements taken at different operating points or temperatures.
Sources and methodology
Method reviewed October 1, 2026. Formulas are implemented independently; references explain the dimensions, ratings or application requirements.
- NIST — SI conversion factors ↗
Declared mechanical horsepower, length, mass, volume and pressure unit conversions; dimensional calculations are derived independently.
- TCI Auto — racing calculations ↗
Empirical quarter-mile ET/trap-speed relationships, tire/gearing RPM and drivetrain calculations. These are estimates, not measured performance.
Frequently asked questions
How does the torque converter k-factor calculation work?
Divide pump RPM by the square root of pump torque in the declared unit system.
Can I compare K-factors with different torque units?
No. K-factor is dimensioned. The numerical values in rpm/√(lb·ft) and rpm/√(N·m) differ.
What do the example values represent?
They demonstrate the method with editable inputs. K-factor carries units and varies across converter speed ratios. Do not compare numerical factors from different torque units.
How should I handle an invalid input?
Enter finite values in the stated units and ranges. Empty required fields, zero denominators and inconsistent geometry hide the previous result and show an input error. Reset example restores the documented scenario.