TORQUE, GEARING & DRIVETRAIN / WORKSHOP TOOL

Torque Converter K-Factor Calculator

Calculate converter k-factor with the declared inputs, then compare the supporting outputs and application limits.

Converter K-factor230.94 rpm/√(lb·ft)Details ↓
01

Your inputs

EDIT TO RECALCULATE
rpm

lb·ft

02

Your result

Converter K-factor
230.94rpm/√(lb·ft)
K-factor using SI torque
198.33 rpm/√(N·m)

Divide pump RPM by the square root of pump torque in the declared unit system.

  • K-factor carries units and varies across converter speed ratios. Do not compare numerical factors from different torque units.
  • Illustrative inputs are editable assumptions. A numerical result does not establish component compatibility or a measured vehicle rating.

Formula and method

Divide pump RPM by the square root of pump torque in the declared unit system.

K-factor = pump RPM / √(pump torque); torque units must be declared

Understanding your inputs

Converter pump speed
Enter rpm. Accepted input range: 0.000001–50000.
Converter pump input torque
Enter lb·ft. Accepted input range: 0.000001–100000.

Worked example

Use the displayed example: Converter pump speed: 4000 rpm; Converter pump input torque: 300 lb·ft. Converter K-factor is 230.94 rpm/√(lb·ft). Companion outputs use the same example inputs unless separately labelled.

Example inputs
Converter pump speed
4000 rpm
Converter pump input torque
300 lb·ft

Default result: Converter K-factor: 230.94 rpm/√(lb·ft).

Assumptions

  • The example is Converter pump speed: 4000 rpm; Converter pump input torque: 300 lb·ft.
  • Illustrative inputs are editable assumptions. A numerical result does not establish component compatibility or a measured vehicle rating.

Limitations

  • K-factor carries units and varies across converter speed ratios. Do not compare numerical factors from different torque units.
  • Illustrative inputs are editable assumptions. A numerical result does not establish component compatibility or a measured vehicle rating.

Common mistakes

  • Entering values in units different from the selected or displayed labels (rpm, lb·ft).
  • No. K-factor is dimensioned. The numerical values in rpm/√(lb·ft) and rpm/√(N·m) differ.
  • Combining measurements taken at different operating points or temperatures.

Sources and methodology

Method reviewed October 1, 2026. Formulas are implemented independently; references explain the dimensions, ratings or application requirements.

Frequently asked questions

How does the torque converter k-factor calculation work?

Divide pump RPM by the square root of pump torque in the declared unit system.

Can I compare K-factors with different torque units?

No. K-factor is dimensioned. The numerical values in rpm/√(lb·ft) and rpm/√(N·m) differ.

What do the example values represent?

They demonstrate the method with editable inputs. K-factor carries units and varies across converter speed ratios. Do not compare numerical factors from different torque units.

How should I handle an invalid input?

Enter finite values in the stated units and ranges. Empty required fields, zero denominators and inconsistent geometry hide the previous result and show an input error. Reset example restores the documented scenario.