SUSPENSION, STEERING & HANDLING / WORKSHOP TOOL

Shock Force Calculator

Use a supplied linear damper coefficient and signed gas contribution for the selected direction.

Net resisting force in linear scenario350.000 NDetails ↓
01

Your inputs

EDIT TO RECALCULATE
N·s/m

mm/s

N

02

Your result

Net resisting force in linear scenario
350.000N
Viscous damping force
250.000 N
Gas force magnitude
100.000 N

Use a supplied linear damper coefficient and signed gas contribution for the selected direction.

  • Real dampers are nonlinear and velocity-dependent. Negative net extension resistance means gas force exceeds damping in this scenario.
  • Example values demonstrate arithmetic. Use measurements, component specifications and applicable requirements for your actual vehicle.

Formula and method

Use a supplied linear damper coefficient and signed gas contribution for the selected direction.

Fviscous = c × shaft speed

Compression resistance = Fviscous + Fgas

Extension resistance = Fviscous − Fgas

Understanding your inputs

Linear damping coefficient
Enter N·s/m. Accepted input range: 0.000001–1000000.
Damper shaft speed magnitude
Enter mm/s. Accepted input range: 0–5000.
Measured gas extension force
Enter N. Accepted input range: 0–10000.
Stroke direction
Compression or Extension

Worked example

Example inputs: Linear damping coefficient: 2500 N·s/m; Damper shaft speed magnitude: 100 mm/s; Measured gas extension force: 100 N; Stroke direction: Compression. Net resisting force in linear scenario: 350.000 N. Independent companion modules use their separately labelled inputs.

Example inputs
Linear damping coefficient
2500 N·s/m
Damper shaft speed magnitude
100 mm/s
Measured gas extension force
100 N
Stroke direction
Compression

Default result: Net resisting force in linear scenario: 350.000 N.

Assumptions

  • Use consistent units and measurements from the same operating point.
  • Displayed example quantities demonstrate arithmetic and are not prescriptions.

Limitations

  • Real dampers are nonlinear and velocity-dependent. Negative net extension resistance means gas force exceeds damping in this scenario.

Common mistakes

  • Entering an outside dimension when the field requires a pitch, internal or effective dimension.
  • Treating supplied rates, coefficients, quotes or appraisals as a live database.
  • Real dampers are nonlinear and velocity-dependent. Negative net extension resistance means gas force exceeds damping in this scenario.

Sources and methodology

Method reviewed October 1, 2026. Formulas are implemented independently; references explain the dimensions, ratings or application requirements.

  • Eibach — suspension worksheet ↗

    Motion ratio, angle correction, wheel rate and ride frequency. Hardpoint intersections and handling geometry are separately derived idealized models.

  • NIST — SI conversion factors ↗

    Declared mechanical horsepower, length, mass, volume and pressure unit conversions; dimensional calculations are derived independently.

Frequently asked questions

What does this shock force result represent?

Use a supplied linear damper coefficient and signed gas contribution for the selected direction.

Which application limits should I check?

Real dampers are nonlinear and velocity-dependent. Negative net extension resistance means gas force exceeds damping in this scenario.

Can I reuse the displayed example as a specification?

Use the example to understand the arithmetic. Replace all assumptions with measurements, applicable manufacturer specifications or current transaction quotes.