RV Air Conditioner Size Calculator

Sum supplied conductive and other heat gains, then compare with manufacturer capacity at actual conditions.

RV heat-load scenario9,076.297 BTU/hDetails ↓
01

Your inputs

EDIT TO RECALCULATE
W/K

°C

°C

W

count

W

W

BTU/h

%

02

Your result

RV heat-load scenario
9,076.297BTU/h
Available entered cooling capacity
11,475.000 BTU/h
Cooling-capacity margin
2,398.703 BTU/h
Total supplied heat load
2,660.000 W

Sum supplied conductive and other heat gains, then compare with manufacturer capacity at actual conditions.

  • Humidity/latent load, leakage and transient heat storage must be represented in supplied gains. This is not a universal BTU-per-RV-length sizing rule.
  • Example values demonstrate arithmetic. Use measurements, component specifications and applicable requirements for your actual vehicle.

Formula and method

Sum supplied conductive and other heat gains, then compare with manufacturer capacity at actual conditions.

Heat gain W = UA × max(0, outdoor−indoor temperature) + solar + occupants + devices/ventilation

BTU/h = W × 3.412141633

Understanding your inputs

Supplied total conductive heat-transfer coefficient
Enter W/K. Accepted input range: 0.000001–10000.
Design outdoor temperature
Enter °C. Accepted input range: -30–70.
Target indoor temperature
Enter °C. Accepted input range: -30–60.
Documented solar heat gain
Enter W. Accepted input range: 0–20000.
Occupant count
Enter count, as a whole number. Accepted input range: 0–20.
Supplied heat gain per occupant
Enter W. Accepted input range: 0–1000.
Device and ventilation heat gain
Enter W. Accepted input range: 0–20000.
Air-conditioner nameplate capacity
Enter BTU/h. Accepted input range: 0.000001–100000.
Documented capacity fraction at conditions
Enter %. Accepted input range: 0.000001–100.

Worked example

Example inputs: Supplied total conductive heat-transfer coefficient: 80 W/K; Design outdoor temperature: 38 °C; Target indoor temperature: 24 °C; Documented solar heat gain: 1000 W; Occupant count: 2 count; Supplied heat gain per occupant: 120 W; Device and ventilation heat gain: 300 W; Air-conditioner nameplate capacity: 13500 BTU/h; Documented capacity fraction at conditions: 85 %. RV heat-load scenario: 9,076.297 BTU/h. Independent companion modules use their separately labelled inputs.

Example inputs
Supplied total conductive heat-transfer coefficient
80 W/K
Design outdoor temperature
38 °C
Target indoor temperature
24 °C
Documented solar heat gain
1000 W
Occupant count
2 count
Supplied heat gain per occupant
120 W
Device and ventilation heat gain
300 W
Air-conditioner nameplate capacity
13500 BTU/h
Documented capacity fraction at conditions
85 %

Default result: RV heat-load scenario: 9,076.297 BTU/h.

Assumptions

  • Use consistent units and measurements from the same operating point.
  • Displayed example quantities demonstrate arithmetic and are not prescriptions.

Limitations

  • Humidity/latent load, leakage and transient heat storage must be represented in supplied gains. This is not a universal BTU-per-RV-length sizing rule.

Common mistakes

  • Entering an outside dimension when the field requires a pitch, internal or effective dimension.
  • Treating supplied rates, coefficients, quotes or appraisals as a live database.
  • Humidity/latent load, leakage and transient heat storage must be represented in supplied gains. This is not a universal BTU-per-RV-length sizing rule.

Sources and methodology

Method reviewed October 1, 2026. Formulas are implemented independently; references explain the dimensions, ratings or application requirements.

  • Dometic — RV air conditioning ↗

    Application-specific rated cooling capacity. The heat-gain balance is independently derived from user-supplied envelope, solar and internal gains; no universal RV-length rule is supplied.

  • NIST — SI conversion factors ↗

    Declared mechanical horsepower, length, mass, volume and pressure unit conversions; dimensional calculations are derived independently.

Frequently asked questions

What does this rv air conditioner size result represent?

Sum supplied conductive and other heat gains, then compare with manufacturer capacity at actual conditions.

Which application limits should I check?

Humidity/latent load, leakage and transient heat storage must be represented in supplied gains. This is not a universal BTU-per-RV-length sizing rule.

Can I reuse the displayed example as a specification?

Use the example to understand the arithmetic. Replace all assumptions with measurements, applicable manufacturer specifications or current transaction quotes.