Formula and method
Sum supplied conductive and other heat gains, then compare with manufacturer capacity at actual conditions.
Heat gain W = UA × max(0, outdoor−indoor temperature) + solar + occupants + devices/ventilation
BTU/h = W × 3.412141633
Understanding your inputs
- Supplied total conductive heat-transfer coefficient
- Enter W/K. Accepted input range: 0.000001–10000.
- Design outdoor temperature
- Enter °C. Accepted input range: -30–70.
- Target indoor temperature
- Enter °C. Accepted input range: -30–60.
- Documented solar heat gain
- Enter W. Accepted input range: 0–20000.
- Occupant count
- Enter count, as a whole number. Accepted input range: 0–20.
- Supplied heat gain per occupant
- Enter W. Accepted input range: 0–1000.
- Device and ventilation heat gain
- Enter W. Accepted input range: 0–20000.
- Air-conditioner nameplate capacity
- Enter BTU/h. Accepted input range: 0.000001–100000.
- Documented capacity fraction at conditions
- Enter %. Accepted input range: 0.000001–100.
Worked example
Example inputs: Supplied total conductive heat-transfer coefficient: 80 W/K; Design outdoor temperature: 38 °C; Target indoor temperature: 24 °C; Documented solar heat gain: 1000 W; Occupant count: 2 count; Supplied heat gain per occupant: 120 W; Device and ventilation heat gain: 300 W; Air-conditioner nameplate capacity: 13500 BTU/h; Documented capacity fraction at conditions: 85 %. RV heat-load scenario: 9,076.297 BTU/h. Independent companion modules use their separately labelled inputs.
Example inputs
- Supplied total conductive heat-transfer coefficient
- 80 W/K
- Design outdoor temperature
- 38 °C
- Target indoor temperature
- 24 °C
- Documented solar heat gain
- 1000 W
- Occupant count
- 2 count
- Supplied heat gain per occupant
- 120 W
- Device and ventilation heat gain
- 300 W
- Air-conditioner nameplate capacity
- 13500 BTU/h
- Documented capacity fraction at conditions
- 85 %
Default result: RV heat-load scenario: 9,076.297 BTU/h.
Assumptions
- Use consistent units and measurements from the same operating point.
- Displayed example quantities demonstrate arithmetic and are not prescriptions.
Limitations
- Humidity/latent load, leakage and transient heat storage must be represented in supplied gains. This is not a universal BTU-per-RV-length sizing rule.
Common mistakes
- Entering an outside dimension when the field requires a pitch, internal or effective dimension.
- Treating supplied rates, coefficients, quotes or appraisals as a live database.
- Humidity/latent load, leakage and transient heat storage must be represented in supplied gains. This is not a universal BTU-per-RV-length sizing rule.
Sources and methodology
Method reviewed October 1, 2026. Formulas are implemented independently; references explain the dimensions, ratings or application requirements.
- Dometic — RV air conditioning ↗
Application-specific rated cooling capacity. The heat-gain balance is independently derived from user-supplied envelope, solar and internal gains; no universal RV-length rule is supplied.
- NIST — SI conversion factors ↗
Declared mechanical horsepower, length, mass, volume and pressure unit conversions; dimensional calculations are derived independently.
Frequently asked questions
What does this rv air conditioner size result represent?
Sum supplied conductive and other heat gains, then compare with manufacturer capacity at actual conditions.
Which application limits should I check?
Humidity/latent load, leakage and transient heat storage must be represented in supplied gains. This is not a universal BTU-per-RV-length sizing rule.
Can I reuse the displayed example as a specification?
Use the example to understand the arithmetic. Replace all assumptions with measurements, applicable manufacturer specifications or current transaction quotes.