Formula and method
The density mode compares dry-air densities at an explicit reference of 101.325 kPa and 15 °C. The documented mode applies the supplied factor.
Dry-air density = (station pressure − vapor pressure) / (287.05 × K)
Density proxy factor = reference dry density / observed dry density
Corrected HP = entered HP × selected correction factor
Understanding your inputs
- Power unit
- Mechanical horsepower or Kilowatts
- Power
- Enter hp. Accepted input range: 0.000001–100000.
- Correction method
- Ideal dry-air density proxy or Enter documented correction factor
- Standard-atmosphere altitude
- Enter ft. Accepted input range: -1000–35000.
- Observed intake temperature
- Enter °F. Accepted input range: -22–140.
- Relative humidity
- Enter %. Accepted input range: 0–100.
- Factor from dyno report / applicable standard
- Enter ratio. Accepted input range: 0.000001–3.
Worked example
Use the displayed example: Power unit: Mechanical horsepower; Power: 300 hp; Correction method: Ideal dry-air density proxy; Standard-atmosphere altitude: 1000 ft; Observed intake temperature: 80 °F; Relative humidity: 40 %. Applied correction factor is 1.0937 ratio. Companion outputs use the same example inputs unless separately labelled.
Example inputs
- Power unit
- Mechanical horsepower
- Power
- 300 hp
- Correction method
- Ideal dry-air density proxy
- Standard-atmosphere altitude
- 1000 ft
- Observed intake temperature
- 80 °F
- Relative humidity
- 40 %
Default result: Applied correction factor: 1.0937 ratio.
Assumptions
- The example is Power unit: Mechanical horsepower; Power: 300 hp; Correction method: Ideal dry-air density proxy; Standard-atmosphere altitude: 1000 ft; Observed intake temperature: 80 °F; Relative humidity: 40 %.
- Illustrative inputs are editable assumptions. A numerical result does not establish component compatibility or a measured vehicle rating.
Limitations
- Density mode is not SAE J1349, SAE J607, DIN or an approved dyno correction. It substitutes standard-atmosphere pressure for measured station pressure.
- Illustrative inputs are editable assumptions. A numerical result does not establish component compatibility or a measured vehicle rating.
Common mistakes
- Entering values in units different from the selected or displayed labels (hp, ft, °F, %).
- No. It is explicitly a dry-air-density proxy. To apply a documented dyno correction, choose the supplied-factor mode and enter the factor from the report or applicable standard.
- Combining measurements taken at different operating points or temperatures.
Sources and methodology
Method reviewed October 1, 2026. Formulas are implemented independently; references explain the dimensions, ratings or application requirements.
- NASA Glenn — metric atmosphere model ↗
Tropospheric pressure, temperature and density curve fit; power proportional to density is our explicitly stated scenario assumption.
- NASA Glenn — gas equation of state ↗
Pressure, absolute temperature and ideal-gas density. Power extrapolation is a scenario, not a manufacturer-certified power law.
- NIST — SI conversion factors ↗
Declared mechanical horsepower, length, mass, volume and pressure unit conversions; dimensional calculations are derived independently.
Frequently asked questions
How does the dyno correction factor calculation work?
The density mode compares dry-air densities at an explicit reference of 101.325 kPa and 15 °C. The documented mode applies the supplied factor.
Is density mode an SAE dyno correction?
No. It is explicitly a dry-air-density proxy. To apply a documented dyno correction, choose the supplied-factor mode and enter the factor from the report or applicable standard.
What do the example values represent?
They demonstrate the method with editable inputs. Density mode is not SAE J1349, SAE J607, DIN or an approved dyno correction. It substitutes standard-atmosphere pressure for measured station pressure.
How should I handle an invalid input?
Enter finite values in the stated units and ranges. Empty required fields, zero denominators and inconsistent geometry hide the previous result and show an input error. Reset example restores the documented scenario.