Formula and method
Average rate = load increase / reduction in height.
Average spring rate = (second load − first load) / (first height − second height)
Understanding your inputs
- First spring test height
- Enter in. Accepted input range: 0.000001–10.
- Second spring test height
- Enter in. Accepted input range: 0.000001–10.
- Load at first height
- Enter lbf. Accepted input range: 0–10000.
- Load at second height
- Enter lbf. Accepted input range: 0–10000.
Worked example
Use the displayed example: First spring test height: 1.8 in; Second spring test height: 1.2 in; Load at first height: 120 lbf; Load at second height: 360 lbf. Average spring rate is 400.00 lbf/in. Companion outputs use the same example inputs unless separately labelled.
Example inputs
- First spring test height
- 1.8 in
- Second spring test height
- 1.2 in
- Load at first height
- 120 lbf
- Load at second height
- 360 lbf
Default result: Average spring rate: 400.00 lbf/in.
Assumptions
- The example is First spring test height: 1.8 in; Second spring test height: 1.2 in; Load at first height: 120 lbf; Load at second height: 360 lbf.
- Illustrative inputs are editable assumptions. A numerical result does not establish component compatibility or a measured vehicle rating.
Limitations
- Spring rate can vary with compression. This interpolation does not establish coil-bind, fatigue or surge limits.
- Illustrative inputs are editable assumptions. A numerical result does not establish component compatibility or a measured vehicle rating.
Common mistakes
- Entering values in units different from the selected or displayed labels (in, in, lbf, lbf).
- Treating a dimensional or empirical estimate as an engine rating or component compatibility check.
- Combining measurements taken at different operating points or temperatures.
Sources and methodology
Method reviewed October 1, 2026. Formulas are implemented independently; references explain the dimensions, ratings or application requirements.
- COMP Cams — valve springs ↗
Installed height, seat/open loads and verification of full-lift coil-bind clearance.
- NIST — SI conversion factors ↗
Declared mechanical horsepower, length, mass, volume and pressure unit conversions; dimensional calculations are derived independently.
Frequently asked questions
How does the valve spring rate calculation work?
Average rate = load increase / reduction in height.
What do the example values represent?
They demonstrate the method with editable inputs. Spring rate can vary with compression. This interpolation does not establish coil-bind, fatigue or surge limits.
How should I handle an invalid input?
Enter finite values in the stated units and ranges. Empty required fields, zero denominators and inconsistent geometry hide the previous result and show an input error. Reset example restores the documented scenario.