Formula and method
Duration includes 180° plus both opening and closing offsets; overlap is intake opening plus exhaust closing.
Intake duration = 180° + intake opening BTDC + closing ABDC
Exhaust duration = 180° + opening BBDC + closing ATDC
Signed overlap = intake opening BTDC + exhaust closing ATDC
Understanding your inputs
- Intake opens before TDC (negative = after)
- Enter ° BTDC. Accepted input range: -90–90.
- Intake closes after BDC
- Enter ° ABDC. Accepted input range: -90–180.
- Exhaust opens before BDC
- Enter ° BBDC. Accepted input range: -90–180.
- Exhaust closes after TDC (negative = before)
- Enter ° ATDC. Accepted input range: -90–90.
Worked example
Use the displayed example: Intake opens before TDC (negative = after): 10 ° BTDC; Intake closes after BDC: 50 ° ABDC; Exhaust opens before BDC: 50 ° BBDC; Exhaust closes after TDC (negative = before): 10 ° ATDC. Intake duration at supplied checking height is 240.00 ° crank. Companion outputs use the same example inputs unless separately labelled.
Example inputs
- Intake opens before TDC (negative = after)
- 10 ° BTDC
- Intake closes after BDC
- 50 ° ABDC
- Exhaust opens before BDC
- 50 ° BBDC
- Exhaust closes after TDC (negative = before)
- 10 ° ATDC
Default result: Intake duration at supplied checking height: 240.00 ° crank.
Assumptions
- The example is Intake opens before TDC (negative = after): 10 ° BTDC; Intake closes after BDC: 50 ° ABDC; Exhaust opens before BDC: 50 ° BBDC; Exhaust closes after TDC (negative = before): 10 ° ATDC.
- Illustrative inputs are editable assumptions. A numerical result does not establish component compatibility or a measured vehicle rating.
Limitations
- All events must use the same checking height. Asymmetric lobes can have peak-lift centerlines different from event midpoints.
- Illustrative inputs are editable assumptions. A numerical result does not establish component compatibility or a measured vehicle rating.
Common mistakes
- Entering values in units different from the selected or displayed labels (° BTDC, ° ABDC, ° BBDC, ° ATDC).
- No. The calculated midpoints assume the supplied event definitions. Asymmetric lobes can have a peak-lift centerline elsewhere.
- Combining measurements taken at different operating points or temperatures.
Sources and methodology
Method reviewed October 1, 2026. Formulas are implemented independently; references explain the dimensions, ratings or application requirements.
- COMP Cams — valve timing ↗
Timing events, duration, overlap and the need to use matching checking heights.
- COMP Cams — technical resources ↗
Cam timing, lobe separation, rocker ratio and spring installation terminology. Arithmetic uses the entered specifications; no universal safe clearance is inferred.
- NIST — SI conversion factors ↗
Declared mechanical horsepower, length, mass, volume and pressure unit conversions; dimensional calculations are derived independently.
Frequently asked questions
How does the camshaft calculation work?
Duration includes 180° plus both opening and closing offsets; overlap is intake opening plus exhaust closing.
Are event midpoints always peak-lift centerlines?
No. The calculated midpoints assume the supplied event definitions. Asymmetric lobes can have a peak-lift centerline elsewhere.
What do the example values represent?
They demonstrate the method with editable inputs. All events must use the same checking height. Asymmetric lobes can have peak-lift centerlines different from event midpoints.
How should I handle an invalid input?
Enter finite values in the stated units and ranges. Empty required fields, zero denominators and inconsistent geometry hide the previous result and show an input error. Reset example restores the documented scenario.