ENGINE INTERNALS & VALVETRAIN / WORKSHOP TOOL

Camshaft Calculator

Calculate intake duration at supplied checking height with the declared inputs, then compare the supporting outputs and application limits.

Intake duration at supplied checking height240.00 ° crankDetails ↓
01

Your inputs

EDIT TO RECALCULATE
° BTDC

° ABDC

° BBDC

° ATDC

02

Your result

Intake duration at supplied checking height
240.00° crank
Exhaust duration
240.00 ° crank
Signed valve overlap
20.00 ° crank
Intake event-midpoint centerline
110.00 ° ATDC
Exhaust event-midpoint centerline
110.00 ° BTDC

Duration includes 180° plus both opening and closing offsets; overlap is intake opening plus exhaust closing.

  • All events must use the same checking height. Asymmetric lobes can have peak-lift centerlines different from event midpoints.
  • Illustrative inputs are editable assumptions. A numerical result does not establish component compatibility or a measured vehicle rating.

Formula and method

Duration includes 180° plus both opening and closing offsets; overlap is intake opening plus exhaust closing.

Intake duration = 180° + intake opening BTDC + closing ABDC

Exhaust duration = 180° + opening BBDC + closing ATDC

Signed overlap = intake opening BTDC + exhaust closing ATDC

Understanding your inputs

Intake opens before TDC (negative = after)
Enter ° BTDC. Accepted input range: -90–90.
Intake closes after BDC
Enter ° ABDC. Accepted input range: -90–180.
Exhaust opens before BDC
Enter ° BBDC. Accepted input range: -90–180.
Exhaust closes after TDC (negative = before)
Enter ° ATDC. Accepted input range: -90–90.

Worked example

Use the displayed example: Intake opens before TDC (negative = after): 10 ° BTDC; Intake closes after BDC: 50 ° ABDC; Exhaust opens before BDC: 50 ° BBDC; Exhaust closes after TDC (negative = before): 10 ° ATDC. Intake duration at supplied checking height is 240.00 ° crank. Companion outputs use the same example inputs unless separately labelled.

Example inputs
Intake opens before TDC (negative = after)
10 ° BTDC
Intake closes after BDC
50 ° ABDC
Exhaust opens before BDC
50 ° BBDC
Exhaust closes after TDC (negative = before)
10 ° ATDC

Default result: Intake duration at supplied checking height: 240.00 ° crank.

Assumptions

  • The example is Intake opens before TDC (negative = after): 10 ° BTDC; Intake closes after BDC: 50 ° ABDC; Exhaust opens before BDC: 50 ° BBDC; Exhaust closes after TDC (negative = before): 10 ° ATDC.
  • Illustrative inputs are editable assumptions. A numerical result does not establish component compatibility or a measured vehicle rating.

Limitations

  • All events must use the same checking height. Asymmetric lobes can have peak-lift centerlines different from event midpoints.
  • Illustrative inputs are editable assumptions. A numerical result does not establish component compatibility or a measured vehicle rating.

Common mistakes

  • Entering values in units different from the selected or displayed labels (° BTDC, ° ABDC, ° BBDC, ° ATDC).
  • No. The calculated midpoints assume the supplied event definitions. Asymmetric lobes can have a peak-lift centerline elsewhere.
  • Combining measurements taken at different operating points or temperatures.

Sources and methodology

Method reviewed October 1, 2026. Formulas are implemented independently; references explain the dimensions, ratings or application requirements.

Frequently asked questions

How does the camshaft calculation work?

Duration includes 180° plus both opening and closing offsets; overlap is intake opening plus exhaust closing.

Are event midpoints always peak-lift centerlines?

No. The calculated midpoints assume the supplied event definitions. Asymmetric lobes can have a peak-lift centerline elsewhere.

What do the example values represent?

They demonstrate the method with editable inputs. All events must use the same checking height. Asymmetric lobes can have peak-lift centerlines different from event midpoints.

How should I handle an invalid input?

Enter finite values in the stated units and ranges. Empty required fields, zero denominators and inconsistent geometry hide the previous result and show an input error. Reset example restores the documented scenario.